MICROSCOPE

Posted on at


V

Microscope

From Wikipedia, the free encyclopedia
 
 
This article is about microscopes in general. For light microscopes, see Optical microscope.
Compound Microscope
Uses Small sample observation
Notable experiments
Discovery of cells
Inventor Zacharias Janssen
Related items Optical microscope Electron microscope
 
18th century microscopes from theMusée des Arts et MétiersParis

microscope (from the Ancient Greekμικρόςmikrós, "small" and σκοπεῖν,skopeîn, "to look" or "see") is an instrument used to see objects that are too small for the naked eye. The science of investigating small objects using such an instrument is called microscopyMicroscopic means invisible to the eye unless aided by a microscope.

There are many types of microscopes. The most common (and the first to be invented) is the optical microscope, which uses light to image the sample. Other major types of microscopes are the electron microscope (both thetransmission electron microscope and the scanning electron microscope), theultramicroscope, and the various types of scanning probe microscope.

On October 8, 2014, the Nobel Prize in Chemistry was awarded to Eric Betzig,William Moerner and Stefan Hell for "the development of super-resolvedfluorescence microscopy," which brings "optical microscopy into thenanodimension".[1][2]

 

 

History[edit]

The first microscope to be developed was the optical microscope, although the original inventor is not easy to identify. Evidence points to the first compound microscope appearing in the Netherlands in the late 1590s, probably an invention of eyeglass makers there:[3] Hans Lippershey (who developed an early telescope) and Zacharias Janssen (also claimed as the inventor of the telescope). There are other claims that the microscope and the telescope were invented by Roger Bacon in the 1200s,[4] but this is not substantiated. Giovanni Faber coined the namemicroscope for Galileo Galilei's compound microscope in 1625 [5] (Galileo had called it the "occhiolino" or "little eye").

Rise of modern light microscopy[edit]

The first detailed account of the interior construction of living tissue based on the use of a microscope did not appear until 1644, in Giambattista Odierna's L'occhio della mosca, or The Fly's Eye.[6]

It was not until the 1660s and 1670s that the microscope was used extensively for research in Italy, the Netherlands and England. Marcelo Malpighi in Italy began the analysis of biological structures beginning with the lungs. Robert Hooke'sMicrographia had a huge impact, largely because of its impressive illustrations. The greatest contribution came fromAntonie van Leeuwenhoek who discovered red blood cells and spermatozoa and helped popularise microscopy as a technique. On 9 October 1676, Van Leeuwenhoek reported the discovery of micro-organisms.[6]

The performance of light microscopy depends as much on how the sample is illuminated as on how it is observed. Early instruments were limited until this principle was fully appreciated and developed, and until electric lamps were available as light sources. In 1893 August Köhler developed a key principle of sample illumination, Köhler illumination, which is central to achieving the theoretical limits of light microscopy. This method of sample illumination produces even lighting and overcomes the limited contrast and resolution imposed by early techniques of sample illumination. Further developments in sample illumination came from the discovery of Phase Contrast by Frits Zernike in 1953, and Differential Interference Contrast illumination by Georges Nomarski in 1955; both of which allow imaging of unstained, transparent samples.

Electron microscopy[edit]

 
An ant as imaged using a scanning electron microscope (SEM)

In the early 1900s a significant alternative to light microscopy was developed, using electrons rather than light to generate the image.Ernst Ruska started development of the first electron microscope in 1931 which was the transmission electron microscope (TEM). The transmission electron microscope works on the same principle as an optical microscope but uses electrons in the place of light and electromagnets in the place of glass lenses. Use of electrons instead of light allows a much higher resolution.

Development of the transmission electron microscope was quickly followed in 1935 by the development of the scanning electron microscope by Max Knoll.[7]

Electron microscopes quickly became popular following the Second World War. Ernst Ruska, working at Siemens developed the first commercial transmission electron microscope and major scientific conferences on electron microscopy started being held in the 1950s. In 1965 the first commercial scanning electron microscope was developed by Professor Sir Charles Oatley and his postgraduate student Gary Stewart and marketed by the Cambridge Instrument Company as the "Stereoscan".

Scanning probe microscopy[edit]

The 1980s saw the development of the first scanning probe microscopes. The first was the scanning tunneling microscopein 1981, developed by Gerd Binnig and Heinrich Rohrer. This was closely followed in 1986 with Gerd Binnig, Quate, and Gerber's invention of the atomic force microscope.

Fluorescence and light microscopy[edit]

The most recent developments in light microscope largely centre on the rise of fluorescence microscopy in biology. During the last decades of the 20th century, particularly in the post-genomic era, many techniques for fluorescent labeling ofcellular structures were developed. The main groups of techniques are small chemical staining of cellular structures, for example DAPI to label DNA, use of antibodies conjugated to fluorescent reporters, see immunofluorescence, and fluorescent proteins, such as green fluorescent protein. These techniques use these different fluorophores for analysis of cell structure at a molecular level in both live and fixed samples.

The rise of fluorescence microscopy drove the development of a major modern microscope design, the confocal microscope. The principle was patented in 1957 by Marvin Minsky, although laser technology limited practical application of the technique. It was not until 1978 when Thomas and Christoph Cremer developed the first practical confocal laser scanning microscope and the technique rapidly gained popularity through the 1980s.

Much current research (in the early 21st century) on optical microscope techniques is focused on development ofsuperresolution analysis of fluorescently labeled samples. Structured illumination can improve resolution by around two to four times and techniques like stimulated Emission Depletion microscopy are approaching the resolution of electron microscopes.

Types[edit]

 
Types of microscopes

Microscopes can be separated into several different classes. One grouping is based on what interacts with the sample to generate the image, i.e., light or photons (optical microscopes), electrons (electron microscopes) or a probe (scanning probe microscopes). Alternatively, microscopes can be classed on whether they analyse the sample via a scanning point (confocal optical microscopes, scanning electron microscopes and scanning probe microscopes) or analyse the sample all at once (wide field optical microscope and transmission electron microscopes).

Wide field optical microscopes and transmission electron microscopes both use the theory of lenses (optics for light microscopes andelectromagnet lenses for electron microscopes) in order to magnify the image generated by the passage of a wave transmitted through the sample, or reflected by the sample. The waves used are electromagnetic (in optical microscopes) or electron beams (inelectron microscopes). Resolution in these microscopes is limited by the wavelength of the radiation used to image the sample, where shorter wavelengths allow for a higher resolution.

Scanning optical and electron microscopes, like the confocal microscope and scanning electron microscope, use lenses to focus a spot of light or electrons onto the sample then analyze the reflected or transmitted waves. The point is then scanned over the sample to analyze a rectangular region. Magnification of the image is achieved by displaying the data from scanning a physically small sample area on a relatively large screen. These microscopes have the same resolution limit as wide field optical, probe, and electron microscopes.

Scanning probe microscopes also analyze a single point in the sample and then scan the probe over a rectangular sample region to build up an image. As these microscopes do not use electromagnetic or electron radiation for imaging they are not subject to the same resolution limit as the optical and electron microscopes described above.

Optical[edit]

Main article: Optical microscope

The most common type of microscope (and the first invented) is the optical microscope. This is an optical instrumentcontaining one or more lenses producing an enlarged image of a sample placed in the focal plane. Optical microscopes have refractive glass and occasionally of plastic or quartz, to focus light into the eye or another light detector. Mirror-based optical microscopes operate in the same manner. Typical magnification of a light microscope, assuming visible range light, is up to 1250x with a theoretical resolution limit of around 0.250 micrometres or 250 nanometres. This limits the practical magnification limit to ~1500x. Specialized techniques (e.g., scanning confocal microscopyVertico SMI) may exceed this magnification but the resolution is diffraction limited. The use of shorter wavelengths of light, such as the ultraviolet, is one way to improve the spatial resolution of the optical microscope, as are devices such as the near-field scanning optical microscope.
Sarfus, a recent optical technique increases the sensitivity of standard optical microscope to a point it becomes possible to directly visualize nanometric films (down to 0.3 nanometre) and isolated nano-objects (down to 2 nm-diameter). The technique is based on the use of non-reflecting substrates for cross-polarized reflected light microscopy.

Ultraviolet light enables the resolution of microscopic features, as well as to image samples that are transparent to the eye. Near infrared light can be used to visualize circuitry embedded in bonded silicon devices, since silicon is transparent in this region of wavelengths.

In fluorescence microscopy, many wavelengths of light, ranging from the ultraviolet to the visible can be used to cause samples to fluoresce to allow viewing by eye or with the use of specifically sensitive cameras.

Phase contrast microscopy is an optical microscopy illumination technique in which small phase shifts in the light passing through a transparent specimen are converted into amplitude or contrast changes in the image. The use of phase contrast does not require staining to view the slide. This microscope technique made it possible to study the cell cycle in live cells.

The traditional optical microscope has more recently evolved into the digital microscope. In addition to, or instead of, directly viewing the object through the eyepieces, a type of sensor similar to those used in a digital camera is used to obtain an image, which is then displayed on a computer monitor. These sensors may use CMOS or charge-coupled device (CCD) technology, depending on the application.

Electron[edit]

Main article: Electron microscope

Three major types of electron microscopes exist:

Scanning probe[edit]

Of these techniques AFM and STM are the most commonly used.

Other types[edit]

 
Different microscopes

Scanning acoustic microscopes use sound waves to measure variations in acoustic impedance. Similar to Sonar in principle, they are used for such jobs as detecting defects in the subsurfaces of materials including those found in integrated circuits. On February 4, 2013, Australian engineers built a "quantum microscope" which provides unparalleled precision.[10]V



About the author

160